Untitled Document
 
HOME>ÀÚµ¿È­±â°è>SHWTM-0416..   

Function

   Self healing ¡æ Welding ¡æ Taping ¡æ
   Silicon Coating ¡æ Capacitance Measuring


Specification

¨ç ELEMENT APPLICATION SIZE

   L : 7.5(MIN.) ~ 30(MAX.) mm
   H : 5.0(MIN.) ~ 20(MAX.) mm
   T : 2.5(MIN.) ~ 20(MAX.) mm

¨è APPLICABLE ELEMENT SIZE
   
* SCOPE OF MEASURE
APPLICABLE AL BAR (A,B,C STANDARD)
A600, B12, C12 (mm)
* XHANGEABLE THROUGH DISCUSSION
ELEMENT TAPING INTERVAL(D,E,F STANDARD D <40>, E<Variable>, F<21~22>)
* D is coordinatable, but fixed in one way in production after discussion.

¨é WELDING FEATURES
* SELECTOR OF ELEMENT METAL I COIN OF METAL LEAF SHAPE
* LEAD LENGTH 32 ~ 40 mm
* WIRE DIA : ¥Õ0.6 ~ ¥Õ1.0mm (MAT' L : CP or CU)
* WELD TIMER : CHANGEABLE USING THE CONTROL BOX(DC 1~15CYCLE)
* TRANS : 3KWA (50% RATE FUSE) : 2EA
* TEST OF WELD' G STRENGTH : 200g ~ 1.0kg

¨ê CAPACITANCE MEASURING MACHINE (Optional)

* MEASUREMENT RANGE : 10§Ü ~ 2§Þ
* MEASUREMENT RANGE : 0.2/2/20/200/2000§Þ
* VALID RANGE OF INDICATION : 100~1999
* RESOLVABILITY : 0.001§Ý (0.2§Ý RANGE)
* ERROR : ¡¾2%(2DIGT of indication)
* POWER SOURCE : 100V X 60Hz

¨ë OTHER FEATERS

* AIR PRESSURE : NORMAL 5bar
* POWER SOURCE : 220~250V X 3¥Õ X 50/60Hz (4KV A)
* BOWL FEEDER : ¥Õ320
* SIZE : 2450W X 1450D X 1600H (mm)
* CAPACITY : 80pcs/min
* WEIGHT : Approx. 700kg


Features

* FILM CAPACITOR ELEMENT SOLDERED or METAL SPRAYED on both sides is put into the    HOPPER of the machine
* It positions element put through the bowl linear feeder.
* It performs self healing process ot the element.
* The function to detect the ineligibility of element capacity is added.
* It can check welding strength of the lead wire.
* It features the function of taping on the AL-BAR and silicon coating of the lead wire.
* Three kinds of process are cut into single process.
* AL-BAR is supplied automatically.(option)
* It can be selected five kinds of element taping intervals thus element taping interval can also be    determined freely.
* It is able to detect (recognize) insertion of element, welding condition and ineligibility of element    capacity.
* An SCR type circuit is installed.

 
 
 
 
 
 
Untitled Document